Premier Specification Comparison

  Premier

170
Premier

350

Premier

350 DF

Premier

80
Heat Rating
Intermediate Input/Output (Btu/h) - 175,000 - -
Max (Input/Output) (Btu/h) 170,000 350,000 350,000 80,000
Configurations Available
Ignition Type Direct Spark Direct Spark Direct Spark Direct Spark
Heated Air Output
Heated Air Output (CFM) 1200 2400 2400 450
Fuel Types Available
Dual Fuel (LPG/NG) N/A N/A Yes N/A
Fuel Consumption (max)
LPG (lbs./hr.) 7.9 16.2 16.2 3.7
NG (cu. ft./hr.) 170.0 350.0 350.0 80
Inlet Gas Pressure
LPG min/max (W.C.) 11.0 / 13.5 11.0 / 13.5 11.0 / 13.5 11 / 13.5
NG min/max (W.C.) 7.0 / 13.5 7.0 / 13.5 11.0 / 13.5 7 / 13.5
Electrical Supply
Amps (Starting/Cont. Oper.) 8 / 2.5 30.0 / 14.0 30.0 / 14.0 5 / 1.5
Electrical Requirements (Volts/Hz/Phase) 115 / 60 / 1 115 / 60 / 1 115 / 60 / 1 115 / 60 / 1
Dimensions
Height (in.) 28.0 41.0 41.0 20.0
Length (in.) 31.0 48.0 48.0 29.5
Width (in.) 18.0 22.0 22.0 13.5
Weight
Net Weight (lbs.) 126 295 295 67
Shipping Weight (lbs.) 134 320 320 74
Materials
Case Material Tri-Shield Steel Tri-Shield Steel Tri-Shield Steel Tri-Shield Steel
Add'l Features/Options
Ducting Opt. Opt. Opt. Opt.
Gas Hose (10ft U.S./15ft. Can) Std. N/A N/A Std.
Gas Hose (15ft U.S./15ft. Can) N/A Std. Std. N/A
Gas Pressure Regulator (with POL) Std. Std. Std. Std.
Thermostat (w/ 20 ft cord) Std. Std. Std. Std.
Certifications
CSA-Canada Yes Yes Yes Yes
CSA-U.S. Yes Yes Yes Yes