- 3,000 - 4,500 sq. ft. standard
Varies based on soil conditions. Complete a Ground Heaters' Thaw Cost Plan.
- up to 6,000 sq. ft. standard
Varies based on application. Complete a Ground Heaters' Cure Cost Plan.
Thaw and cure large areas:
| Length | 181" |
| Width | 91" |
| Height | 93" |
| Ground clearance | 12" |
| Appx. Weight w/o fuel | 5,580/6,105 lbs |
| Appx. Weight with fuel | 7,190/7,715 lbs |
| Fuel capacity | 230 US GAL |
| Heat Transfer Fluid | 115 US GAL |
| Pumps, 265 gph positive displacement | 2 |
| Hose (2 x 1500 ft) | 3,000 ft |
| Hose reels | 2 |
| Hose rewind | 120V AC electric, w/ 12V DC clutch |
| Circulation loops | 2 |
| Tires | ST215/75D14 |
| Hitch | pintle or 25/16" ball |
| Brakes | 12V DC electric |
| Tie Downs (for transport) | 4 |
| Ground fault interrupt | yes |
| Main circuit breakers | 2 |
| Burner motor thermal protection | manual reset |
| Burner Ignition | electronic |
| High temperature shutdown | yes |
| No-flame shutdown | yes |
| Low fluid shutdown/warning light | yes |
| Vented closed loop circulation | yes |
| Hydronic heater operating pressure | 0 psi |
| Temperature gauges | 5 |
| Pressure gauges | 2 |
| Interior light, 120V AC | 1 |
| Heater, gross output | 385,000 BTU/H |
| Heater, net output | 321,000 BTU/H |
| Heater, efficiency | 83% |
| Temperature controller | digital |
| Fuel consumption at full load | 2.75/3.17 US GPH |
| Fuel requirement | winter blend diesel |
| Run time | up to 140 hours |
| Electrical requirement | 2 x 20 amps x 120V AC |
| Normal operating temp | 100°F - 180°F |
| Normal hose operating press. | 90-110 psi |
| HTF flow rate per loop | 265 US GPH |
| Thawing capacity (std equipment) | 3,000-6,000 sq ft |
| Thawing capacity (w/ accessories) | up to 6,000 sq ft |
| Curing capacity (std equipment) | 6,000 sq ft |
| Curing capacity (w/ accessories) | up to 18,000 sq ft |
| Frost Prevention (std equipment) | up to 9,000 sq ft |
| Frost Prevention (w/ accessories) | up to 27,000 sq ft |
| Air heat capacity (w/ accessories) | 535,000 sq ft |
| Performance monitoring system | yes |